Compliant disposal of Fats, Oils and Grease (FOG) is one of the greatest challenges to successful operation of our community’s sewer system.

When FOG materials are improperly dumped or washed down the drain, they cause blockages in the sewer and create overflows of raw sewage into our waters. Not only are blockages bad for water quality, but they can result in additional charges beyond your sewer rates (extra cleaning, emergency response, violations and fines, etc.). FOG can also cause plumbing backups.

For companies managing FOG materials and disposal, annual permits are required and the application can be completed and submitted online below. 

FOG Application, Rules & Regulations

  • The York Sewer District has recently updated its sewer use regulations and applications to better protect our waterways and beaches. These new regulations may require you to modify your facility’s operations. IMPORTANT:  GARBAGE DISPOSALS ARE NOT PERMITTED 
  • FOG PERMITS MUST BE RENEWED ANNUALLY
  • FOG permit application forms can now be submitted online
FOG Program Permit Online Application 

Please complete and submit all sections of this application. 


SECTION A — ESTABLISHMENT INFORMATION

SECTION B — FACILITY OPERATIONAL CHARACTERISTICS

SECTION C — GREASE TRAP / INTERCEPTOR INFORMATION
Confirm e-Signature
Read our Electronic Record and Signature Disclosure
Streamline Verify
There was a problem saving your submission. Please try again later.
Please wait while your submission is being saved...
Thank you, your submission has been received.
FOG Program Permit Details, PDF Resources 
Grease Trap and Interception FAQs 
  • Does a facility need a Grease Trap or Interceptor? All Food Services Establishments (FSEs) must be equipped with Grease Interceptors and/or Grease Traps designed to limit the discharge of grease and oil to the public sewer system.
     
  • What fixtures/drains should be connected to the Grease Interceptor? All wastewater from food preparation operations and/or washing and clean-up operations, including but not limited to pot sinks, pre-rinse stations, work stations, soup kettles, braising pans, mop sinks and wastewater generated from exhaust fan hood cleaning operations must discharge to a grease removal device. All automatic dishwasher wastewater, excluding pre-rinse stations, must bypass the grease removal device and be discharged directly into the sewer system.
     
  • What size grease trap/interceptor? Grease Interceptors must have a minimum depth of 4 feet and a minimum capacity of one thousand gallons and must have sufficient capacity to provide at least 24 hour detention period for the process flow. The minimum process flow must be based on 30 gallons per seat/chair per day or based upon actual water usage for existing facilities. Grease Traps must have a minimum capacity of 25 gpm flow. For more sizing information on Grease Interceptors refer to the Uniform Plumbing Code 1014-0.
     
  • How often should Grease Traps/Interceptors be maintained? External Grease Interceptors must be inspected monthly by the owner(s) and cleaned by a state licensed septage hauler whenever the level of grease is 25% of the effective depth or at least every three months, whichever is sooner. Internal Grease Traps must be cleaned as needed.
Top 10 FOG Best Practices 
  1. Wipe/Scrape before Washing Wipe or scrape food residue into the trash from pots, pans, dishware, and work areas before washing
  2. Dispose of Food Directly into the Trash  Keep your grease removal device functioning properly and minimize the amount of TSS and BOD entering the sewer system by disposing of excess food and scraps into the trash
  3. Conduct Employee Trainings Regularly train and education employees about proper disposal of fats, oils, and grease
  4. Clean Hood Filters & Mats Clean exhaust filters and kitchen mats in sinks, not outside, to keep pollutants from entering storm drains
  5. Recycle Used Cooking Oil Collect and store used cooking oil in a barrel or bin and use an approved grease hauler for FOG disposal
  6. Protect Drains from Spills Block off sinks or floor drains when FOG spills occur. Use an absorbent material (cat litter or absorbent sweep) to clean up the FOG and dispose of material in the trash
  7. Install Drain Screens Capture scraps and other solid materials by installing drain screens in all sinks: food  floors, mop and hand. Dispose of captured material in the trash.
  8. Install Signage Post instructional signs near sinks and dishwashers
  9. Maintain Grease Removal Devices Learn, schedule and document the grease removal equipment cleaning requirements and ensure that the equipment is maintained on the recommended schedule
  10. Keep Accurate Records Use the YSD Grease Cleaning Record Form checklist and fill in the details for trap or interceptor cleanings, maintenance and service
A circular graphic urging people to "Stop the Clog" by keeping fats, oils, and grease out of York sewers.